Coolator offer practical tools for refrigeration professionals in the daily work
The unit converter is especially aimed at the refrigeration branch and includes the most used units and quantities. The conversion works two ways, which means that you can either enter the value to be converted or the intended result. The line calculation calculates flow values in either liquid or gas lines for various refrigerants and the result is displayed as velocity, volume flow and mass flow.
How to use
Unit conversion:
Select the quantity type, e.g. Velocity, Length etc. that you want units to be converted between.
Select the source or original unit, e.g. m. Then select the target unit, e.g. in.
Now enter the source value, e.g. 15 (m) and the target unit 590.6 (in) is displayed immediately.
If you change the target value, the source value will instantly change.
Line calculation:
Select the line type, liquid or gas, and then select type of refrigerant.
Select the pipe dimension.
Enter the pipe length, the cooling capacity, inlet pressure (the pressure at the beginning of the pipe in question), and the temperature (at the beginning of the pipe in question).
Click Calculate and you will see the results.
Engineering Tomorrow
Danfoss engineers technologies that enable the world of tomorrow to do more with less. We meet the growing need for infrastructure, food supply, energy efficiency and climate-friendly solutions. Our products and services are used in areas such as refrigeration, air conditioning, heating, motor control and mobile machinery. We are also active in the field of renewable energy as well as district heating infrastructure for cities and urban communities. Our innovative engineering dates back to 1933 and today Danfoss is a world-leader, employing 22,500 employees and serving customers in more than 100 countries. We are still privately held by the founding family. Read more about us at www.danfoss.com.
Disclaimer
Coolater (“the Application”) is provided on an “as is” and “as available” basis for the intended purposes as determined by Danfoss only and any use hereof is at the user’s sole risk. The Application and results and information generated thereby cannot substitute technical advice but must be verified by the user, they are not promises and should not be relied on as accurate data or analyses.
Danfoss disclaims all warranties and conditions regarding the Application, whether express, implied, or statutory, including, but not limited to, conditions of merchantability, satisfactory quality, fitness for a particular purpose, accuracy and non-infringement of third parties’ rights. Danfoss does not warrant that the Application will meet your requirements or that the operation hereof will be uninterrupted or error-free.
To the extent not prohibited by law, in no event shall Danfoss be liable for any direct, special, indirect or consequential damages, whatsoever, including, without limitation, damage to property, damages for loss of savings or profits, or loss of data arising out of any use of the Application.
App support coolapp@danfoss.com
Please visit www.danfoss.com for more information and contact details.
For more information about local support please visit http://refrigerationandairconditioning.danfoss.com/contact/